China best High Voltage Three Phase Asynchronous Motor with high quality

Warranty: 12 months
Model Number: YR, YPKK, YRKK
Type: Asynchronous Motor, AC electric motor
Frequency: 50hz/60hz, 50hz/60hz
Phase: Three-phase
AC Voltage: 380v-10000v
Efficiency: IE 2
Insulation class: F; H
Protection class: IP54/IP55
Packaging Details: High voltage motor is packed with Shock absorption,moisture-proof package, standard export wooden case

YKK series 3 phase asynchronous motor YKK400-500, 380 v motor is a protection grade IP44, closed cage type rotor, three-phase asynchronous motor. Protection grade IP44 or IP54, cooling method IC611. The frame and end cover are made of steel plate, adopting box-type structure, the machine inside can be observed when the top cover is opened, all the parts can be removed and installed,easy installation and maintenance. YKK series 3 phase asynchronous motor applications This series motor can be used to drive all kinds of general machinery, such as: compressor, water pump, fan, crusher, cut machine, transportation machinery and other mechanical equipment . Running as a prime mover,in mining, mechanical industry, power plants. various kinds of industrial and mining enterprises.to drag the blower, coal pulverizer,steel rolling mill, windlass. Notice for YKK series 3 phase asynchronous motor This series motor structure and installation type is IMB3, quota is based on continuously (S1) continuous norm, frequency is 50 Hz,rated voltage is 380 v, other voltage grade or other special requirements can be required when placing an order. TypePowerRated CurrentPoleYKKkwAYKK3551-222026.92YKK3553-228034.22YKK3554-425030.44YKK400-3-240047.82YKK4003-431537.84YKK4502-256066.42YKK4503-456066.54YKK4504-271082.92YKK4503-828036.68YKK4502-1571571.910YKK5002-1222031.912YKK5601-21400160.52YKK5603-1063082.910 Y2 series 3 phase asynchronous motor Y2 series 3 phase asynchronous motor is a new series adopting new technology. Y2 series 3 phase asynchronous motor features:1. Y2 series motor is totally enclosed, fan cooled, squirrel cage type structure2. Possinging advantages like new design, beautiful shape, low noise, high efficiency , good starting performance3. Compact structure, convenient use and maintenance. The whole machine adopts class F insulation, the assessment method follows the international practice of insulation structure design, thereby greatly improving the safety and reliability of the motor. CZPT the advanced level of the similar foreign products in the early nineties.Y2 series 3 phase asynchronous motor applications Y2 series motors can be widely used in machine tools, fan, water pump, compressor and transportation, agriculture, food processing and other kinds of mechanical equipment. Contact Us If you would like to know more about water pumps models or price, please feel free to message here or email and Whatsapp. Reply as soon as possible. And online always in working time.

What Is a Gear Motor?

A gear motor is an electric motor coupled with a gear train. It uses either DC or AC power to achieve its purpose. The primary benefit of a gear reducer is its ability to multiply torque while maintaining a compact size. The trade-off of this additional torque comes in the form of a reduced output shaft speed and overall efficiency. However, proper gear technology and ratios provide optimum output and speed profiles. This type of motor unlocks the full potential of OEM equipment.

Inertial load

Inertial load on a gear motor is the amount of force a rotating device produces due to its inverse square relationship with its inertia. The greater the inertia, the less torque can be produced by the gear motor. However, if the inertia is too high, it can cause problems with positioning, settling time, and controlling torque and velocity. Gear ratios should be selected for optimal power transfer.
The duration of acceleration and braking time of a gear motor depends on the type of driven load. An inertia load requires longer acceleration time whereas a friction load requires breakaway torque to start the load and maintain it at its desired speed. Too short a time period can cause excessive gear loading and may result in damaged gears. A safe approach is to disconnect the load when power is disconnected to prevent inertia from driving back through the output shaft.
Inertia is a fundamental concept in the design of motors and drive systems. The ratio of mass and inertia of a load to a motor determines how well the motor can control its speed during acceleration or deceleration. The mass moment of inertia, also called rotational inertia, is dependent on the mass, geometry, and center of mass of an object.
Motor

Applications

There are many applications of gear motors. They provide a powerful yet efficient means of speed and torque control. They can be either AC or DC, and the two most common motor types are the three-phase asynchronous and the permanent magnet synchronous servomotor. The type of motor used for a given application will determine its cost, reliability, and complexity. Gear motors are typically used in applications where high torque is required and space or power constraints are significant.
There are two types of gear motors. Depending on the ratio, each gear has an output shaft and an input shaft. Gear motors use hydraulic pressure to produce torque. The pressure builds on one side of the motor until it generates enough torque to power a rotating load. This type of motors is not recommended for applications where load reversals occur, as the holding torque will diminish with age and shaft vibration. However, it can be used for precision applications.
The market landscape shows the competitive environment of the gear motor industry. This report also highlights key items, income and value creation by region and country. The report also examines the competitive landscape by region, including the United States, China, India, the GCC, South Africa, Brazil, and the rest of the world. It is important to note that the report contains segment-specific information, so that readers can easily understand the market potential of the geared motors market.

Size

The safety factor, or SF, of a gear motor is an important consideration when selecting one for a particular application. It compensates for the stresses placed on the gearing and enables it to run at maximum efficiency. Manufacturers provide tables detailing typical applications, with multiplication factors for duty. A gear motor with a SF of three or more is suitable for difficult applications, while a gearmotor with a SF of one or two is suitable for relatively easy applications.
The global gear motor market is highly fragmented, with numerous small players catering to various end-use industries. The report identifies various industry trends and provides comprehensive information on the market. It outlines historical data and offers valuable insights on the industry. The report also employs several methodologies and approaches to analyze the market. In addition to providing historical data, it includes detailed information by market segment. In-depth analysis of market segments is provided to help identify which technologies will be most suitable for which applications.
Motor

Cost

A gear motor is an electric motor that is paired with a gear train. They are available in AC or DC power systems. Compared to conventional motors, gear reducers can maximize torque while maintaining compact dimensions. But the trade-off is the reduced output shaft speed and overall efficiency. However, when used correctly, a gear motor can produce optimal output and mechanical fit. To understand how a gear motor works, let’s look at two types: right-angle geared motors and inline geared motors. The first two types are usually used in automation equipment and in agricultural and medical applications. The latter type is designed for rugged applications.
In addition to its efficiency, DC gear motors are space-saving and have low energy consumption. They can be used in a number of applications including money counters and printers. Automatic window machines and curtains, glass curtain walls, and banknote vending machines are some of the other major applications of these motors. They can cost up to 10 horsepower, which is a lot for an industrial machine. However, these are not all-out expensive.
Electric gear motors are versatile and widely used. However, they do not work well in applications requiring high shaft speed and torque. Examples of these include conveyor drives, frozen beverage machines, and medical tools. These applications require high shaft speed, so gear motors are not ideal for these applications. However, if noise and other problems are not a concern, a motor-only solution may be the better choice. This way, you can use a single motor for multiple applications.
Motor

Maintenance

Geared motors are among the most common equipment used for drive trains. Proper maintenance can prevent damage and maximize their efficiency. A guide to gear motor maintenance is available from WEG. To prevent further damage, follow these maintenance steps:
Regularly check electrical connections. Check for loose connections and torque them to the recommended values. Also, check the contacts and relays to make sure they are not tangled or damaged. Check the environment around the gear motor to prevent dust from clogging the passageway of electric current. A proper maintenance plan will help you identify problems and extend their life. The manual will also tell you about any problems with the gearmotor. However, this is not enough – it is important to check the condition of the gearbox and its parts.
Conduct visual inspection. The purpose of visual inspection is to note any irregularities that may indicate possible problems with the gear motor. A dirty motor may be an indication of a rough environment and a lot of problems. You can also perform a smell test. If you can smell a burned odor coming from the windings, there may be an overheating problem. Overheating can cause the windings to burn and damage.
Reactive maintenance is the most common method of motor maintenance. In this type of maintenance, you only perform repairs if the motor stops working due to a malfunction. Regular inspection is necessary to avoid unexpected motor failures. By using a logbook to document motor operations, you can determine when it is time to replace the gear motor. In contrast to preventive maintenance, reactive maintenance requires no regular tests or services. However, it is recommended to perform inspections every six months.

China best High Voltage Three Phase Asynchronous Motor  with high qualityChina best High Voltage Three Phase Asynchronous Motor  with high quality